2PIECE air propjet polisher teeth prophy dental 4 holes


brand new 2 pieces medical equipment air propjet polisher polishing dental 4 holes
IMG_4017.jpg picture by biglovehouse
This product is for jetting power, it may clog by moist air or by water. do not use at the delivery system which air pressure may increase rapidly when it clogged.
1), check if the air pressure of the delivery system will not increase extraordinary, when you cover the tip of the syringe.
2),in case of extraordinary increase, check the regulator just before the delivery system.
3),in case of there is no regulator connected, install the regulator with diaphragm valve.
1).connecting powder case to handpiece hose 4-hole,or 2 hole type powder case connect the powder case directly to the corresponding handpiece hose.
2), mounting nozzle to power case slide back the handpiece release ring on the powder case joint and hold. insert the nozzle into the powder case joint, and release the ring.
3). filling cleaning powder unscrew the powder case cap and remove. break a seal of the cleaning powder pack ,and fill whole pack of powder in the powder case. recap the powder case cap securely.
! do not use the left-over powder or the powder in the pack opened days ago, they could get moist and cause clogging of the powder passage
aim the nozzle at the cuspidor, and jet for 3 seconds to vetify that the powder jets uniformly. and use on the patient. use with the nozzle 5-10mm
do not jet the powder directly to the oral soft tissues, gum or subgingiva
Always use the high volume evacauator to prnvent the patient from swallowing the powder. use intermittently and have the patient wash his or her mouth as often as needed
thank you for purchasing Air prophy unit. Read this Operation Manual carefully before use, and file for future reference.
this is for dentists and dental hygienists use only.
Do not use on the follwing patients.
1)Those who requice restrictionon sodium intake.
2)Those with grave ulcers in digestive organs.
3)Those with hepatic disfunction.
4)Those with lung or cardiac disfunction.
5)Those with hyperemia, hemorrhage,or infammation in the oral cavity.
6)Those with damage or abnormality in oral cavity.
7)Those who tend to develop inflammation in the oral mucous membrane.
Do not use a powder case cover if it has cracks or deep scratches in it. Such cover might break but the applied air pressure, and fragments would fly.
Do not hit or impact the power case cover.
Do not expose the powder case cover to Organice Solvents, etc,because it may break.
Powder case cover is a consumption article. It will deteriorate by ultraviolet rays, or by other environment factors. Replace the Powder case cover every six months.
Take the powder case cover and rubber packing once a week, and clean the clung power, When doing this ,check the powder case that it has no cracks or deep scratches on it.
Do not jet directly onto the oral soft tissues or subgingiva.
Use clean and dry air all the time. Moist air could cause the powder to solidify and clog the powder passage.
Care shoulder be exerised to prevent the scattered powder from entering the patient's other mucous membranes then oral, such as eyes and nose.
Use our powder only. In case a trouble takes place with use of other powders, we shall not be held liable to the incident and consequences.
Fill one pack of powder in the powder case for each patient. In case same amount of the powder case unused discard it.
Do not use the powder remained in the pack unused for an extended period of time, to avoid clogging of the device by the moistened powder.
When Air prophy unit id discounnected from the coupling or from the handpiece hose, wipe water from its connecting end and from the hose .Moist powder could cause the powder passage to clog.
To store after use, remove powder from the powder case and clean its interior.
Remove oil, clemicals and other harmful materials from the plastic powder case cover as soon as they are found. Such may cause the cover to break in time.
the manufacturer recommends autoclaving
1Disassemble air prophy unit into the following components.
.powder case into the powder case body and the powder case cap.
.powder case cap into the O-ring, powder case cover ,thin gasket and serrated cover ring.
2),Autoclave for 20min, at 121 or 15min,at 132
3),Prior to use, open the pouch and assemble the nozzle into the powder case. Assemble the powder case cover. Fill opwder in the powder case and assemble the powder case cover to the powder case
.Skip dry cycle if the chamber temperature could exceed 135
Place the pouch in the central or top tray, as the local temperature at the chamber bottom could exceed the set temperature.
.Do not sterilize with other instrumentd that are not completely cleaned from the chemicals. Chemical vapors could set on the air prophy Unit components and cause them to discolor or malfunction.
nombe Trouble probable Cause Remedy
1 No air or powder exits from nozzle (1)The nozzle is clogged Romove the nozzle when no powder in the powder case
.Clean the nozzle and the powder case with the cleaning file .Last puffed it by 3-way syringe. (2)powder case is clogged (fig.7 and fig-8)
nozzle but not in sufficient power. (1)Powder that has been left unused was used Change with new powder.
(2)Water invaded into the drive air passage. Change the O-ring at the coupling end of the powder case.
Check the quality of drived air .Drain the air filter and air compressor.
(3).Air passage is partially blocked Remoe the nozzle .Clean the nozzle, powder case with the supplied wire .(fig6`fig7`fig8)
by the powder solidified by water.
3Water lleaks from the nozzle O-ring is damaged. Change O-rings.
4.Nozzle hardly swivels. Cleaning powder accumulated in the O-ring Remove the O-rings. Brush the Powder off the O-ring grooes and joint. Clean the O-rings. Put them back on the joint.
groove, making the nozzle swivel extremely resistive.
Iran, Iraq, Israel, Cyprus, Rwanda, Hungary, poland,
Czechic, Russia, Latvia, Roumania, Slovak, Esthonia, Ukraine, Korea,
* we recommend "Express Post" to ensure your item can reach you fast and safe. Item sent via regular post may be lost and we will not be held responsible.
We will response any question in 24 hours via email (unless it is weekend and Holiday). We will do our best to resolve your issue.
In order to keep a lower sales cost, we handle the all enquiries through email and therefore pass the savings on offering you the best price! Email: ****@hotmail.com Please make sure your email system accept message from hotmail!



2PIECE air propjet polisher teeth prophy dental 4 holes