For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
* Built in thermometer for HVAC applications
* LoZ: helps prevent false readings due to ghost voltage
Fluke 62 Mini Handheld Infrared Thermometer
Fluke TL75 Hard Point Test Lead Set
* Extremely hard alloy tips resist wear
* Distinctive comfort grip probes
* Economical PVC insulated leads
Fluke TPAK ToolPak Magnetic Meter Hanging Strap
* Hang your meter anywhere...
* 9-inch "hook-and-loop" hanger strap
* 17-inch "hook-and-loop" hanger strap
Fluke 80BK Integrated DMM Temperature Probe
* Convenient one-piece construction for DMMs with temperature function
* K thermocouple with standard banana jack
* Measurement range: -40 to 260 C (-40 to 500 F)
Fluke 80AK-A K-Type Interface Adapter
* Allows the multimeter to be used with any K-type thermocouple probe.
* The 80AK-A adapter does not affect measurement range and accuracy.
Fluke C115 Deluxe carrying case with shoulder strap
* Easy and convenient storage of Fluke meters and accessories
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 95 %.
The accuracy specifications take the form of: ( [ % of Reading ] + [ Counts ] )
Digital: 6,000 counts, updates 4/sec
9 volt Alkaline, NEDA 1604A/IEC 6LR61
Accuracy ([% of reading] + [counts])
Beeper on < 20 O off > 250 O; detects opens or shorts of 500 s or longer.
1.5 % + 3 (2.5 % + 3 > 500 Hz)
All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of = 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.