Fluke 43 power quality analyzer with probe nice


The Fluke 43 Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures. All in a rugged handheld package.
* - Combines the most useful capabilities of a power quality analyzer, multimeter and scope
* -Measure power harmonics and catch intermittents
* -Monitoring functions help track intermittent problems and power system performance
* -Menus use familiar electrical terminology
* -Applications manual, power quality User's Manual explain measurements step-by-step
Input impedance: 1 MW, 20 pF
Voltage Rating: 600V rms, CAT III
Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy: (1% +10 counts)
True-rms current (ac + dc)
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: (0.5% +2 counts)
Ranges: 250 W, 2.50 kW, 25.0 kW, 250 kW, 2.50 MW, 250 MW
Accuracy: (4% + 4 counts)
Displacement Power Factor, DPF
Range: 0.00 to 0.25 Accuracy: Not specified
Range: 0.25 to 1.0 Accuracy: 0.04
Ranges: 1st to 51st harmonic
Accuracy: (3% +2 counts) to (15% +5 counts)
Accuracy: (3% +8 counts) to (5% +8 counts)
Accuracy: (5% +2 counts) to (30% +5 counts)
Ranges: 40 Hz to 70 Hz fundamental
Ranges: 2nd to 51st harmonic
Recording times: 4 min to 16 days (selectable)
Accuracy: (2% +10 counts)
V/A/Hz: Line voltage, current, frequency
Power: Watts, VA, VAR, PF, DPF, frequency
Harmonics: THD, harmonic voltage, (or current, or power), frequency, % of total, phase
Ohms: Ohms, diode, continuity, capacitance
Scope: DC voltage, dc current, ac voltage, ac current, frequency, pulse width, phase, duty cycle, peak max, peak min, peak min-max, crest factor
Minimum pulse width: 40 ns
Voltage threshold settings: 20%, 50%, 100%, 200% above or below normal voltage
Min voltage and max voltage at cursor:
Ranges: 10V, 25V, 50V, 125V, 250V, 500V, 1250V
Accuracy: 5% of full scale
Current ranges: Ranges: 1A, 5A, 10A, 50A, 100A, 500A, 1000A
Inrush times: Ranges: 1s, 5s, 10s, 50s, 100s, 5 min
Cursor readings, Current at cursor
Ranges: 12.5A, 25A, 50A, 125A, 250A, 500A, 1250A, 2500A, 5 kA
Ranges: 4 to 235 pixels (1 pixel = inrush time/250)
Accuracy: (0.2% + 2 pixels)
Time ranges: Ranges: 20 ns/div to 60 s/div
Max sampling rate: Ranges: 25 MS/s
Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads
Current channel [2]: 15 kHz at inputs, 10 kHz with 80i-500s Probe
Vertical sensitivity: Ranges: 5 mV/div to 500V/div
Vertical resolution: 8 bit (256 levels)
Record length: 512 samples per channel
Timebase modes: Normal, roll, single
Pre-trigger: Up to 10 divisions
Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
Ranges: 500.0W, 5.000 kW, 50.00 kW, 500.0 kW, 5.000 MW, 30.00 MW
Accuracy: (0.6% +5 counts)
Diode voltage: Accuracy: (2% +5 counts)
Continuity: Beeper on at < (30W 5W)
Ranges: 50.00 nF, 500.0 nF, 5.000 F, 50.00 F, 500.0 F
Ranges: -100.0 C to 400.0 C, -200.0 F to 800.0 F
Accuracy: (0.5% +5 counts)
Optically Isolated RS-232 Interface
Supports HP Laserjet , Deskjet , Epson FX/LQ and Postscript printers with optional PAC91 Printer Adapter Cable
FlukeView Power Quality Analyzer Software included
FlukeView Power Quality Software
Comes with the test leads, PM 9080 interface(RS232) cable, power supply, 80i-500S current probe, hard case, manuals, connector adaptors.
A nice clean unit, sold with 5 day return priviledge if unhappy



Fluke 43 power quality analyzer with probe nice